Kaifeng Chuangxin Measurement & Control Instrument Co., Ltd.
Business Type:Manufacturer , Trade Company
Main Markets: Africa , Americas , Asia , Caribbean , East Europe , Middle East , North Europe , Oceania , Other Markets
Exporter:1% - 10%
Certs:ISO14001, ISO9001, CE, Test Report
Description:Intellectual Electromagnetic Flow Meter,Samrt Stainless Steel Magnetic Flow Meter,Thread Connection Liquid Electromagnetic Flowmeter
Payment Type:T/T,D/P,L/C,D/A,Paypal
Incoterm:FOB,CFR,CIF,EXW,FCA,CPT,CIP,DDP,DDU
Min. Order:1 Set/Sets
Transportation:Ocean,Land,Air,Express
Port:Shanghai,Qingdao,Tianjin
$289-578 /Set/Sets
Model No.: CXLD-Stainless Steel
Brand: KCMC
Place Of Origin: China
Display Method: Analog And Digital
Material: Stainless Steel
Lining: PTFE
Pressure: 1.6Mpa
Connection: Thread
Power Supply: AC220V
Accuracy: 0.5%
Protection Class: IP65
Packaging: Standard Export Paper Carton
Productivity: 100Sets per month
Transportation: Ocean,Land,Air,Express
Place of Origin: China
Supply Ability: 100 set weekly
Certificate: ISO9001:2015
HS Code: 9026100
Port: Shanghai,Qingdao,Tianjin
Payment Type: T/T,D/P,L/C,D/A,Paypal
Incoterm: FOB,CFR,CIF,EXW,FCA,CPT,CIP,DDP,DDU
Whole Stainless Steel materials Electromagnetic Flow Meter refer to the whole house and measuring tube are both use stainless steel and needn't painting outside, the whole Stainless Steel materials electromagnetic Flow Meter is high explosion-proof and anti-corrosion function Electromagnetic Flowmeter.
Technical parameter of Whole Stainless Steel electromagnetic flow meter are as flollwing:
Lining and nominal diameter DN(mm) : (special specifications can be customized) | PTFE lining:10,15,20,25,32,40,50,65,80,100,125,150,200,250,300,350,400,450,500,600 |
Rubber lining: 80,100,125,150,200,250,300,350,400,450,500,600,800,1000, 1200, 1400, 160 | |
Measurement error | ± 0.5% |
Temperature of measured medium | rubber lining -20℃~ + 80℃, PTFE -20℃ ~ + 180℃ |
Ambient temperature | -25~ + 60 ℃ |
Relative humidity | 5%~95% |
Rated pressure | DN10~65: 4.0MPa; DN80-150:1.6MPa ; DN200-600:1.0MPa |
Flow rate range | 0.1~15m/s |
Conductivity | The conductivity of the measured fluid is not less than 5μs /cm |
Output signal and load resistance | 0~10mA, 0~1000 Ω; 4~20mA, 0~500 Ω |
Electrode material | 316L, Ti, Ta, HB, Pt |
Protection level | Standard IP65, IP67, and optional IP68 |
Straight pipe length: upstream | ≥ 5DN, downstream ≥ 2DN |
Connection | flange connection, thread connection, clamp connection |
Power supply | 90~260AC ± 10%,50Hz ± 5% |
Power consumption | below 20W |