Kaifeng Chuangxin Measurement & Control Instrument Co., Ltd.
Business Type:Manufacturer , Trade Company
Main Markets: Africa , Americas , Asia , Caribbean , East Europe , Middle East , North Europe , Oceania , Other Markets
Exporter:1% - 10%
Certs:ISO14001, ISO9001, CE, Test Report
Description:Integrated Electromagnetic Water Flowmeter,2.6vdc Supply Electromagnetic Flowmeter,Intelligent Electromagnetic Water Flowmeter
Payment Type:T/T
Incoterm:FOB,CIF,EXW,CFR,FCA
Transportation:Ocean,Land,Air,Express
Port:Shanghai,Qingdao,Shenzhen
Model No.: CXLDS
Brand: CX
Display Method: Analog And Digital
Material: SS304&Carbon steel
Liner: PTFE
Power Supply: Lithium Battery
Protection Class: IP65
Accuracy: 1.0
Max. Pressure: 1.6MPa
Packaging: Standard fumigation-free Plywood case
Productivity: 800 set per month
Transportation: Ocean,Land,Air,Express
Place of Origin: China
Supply Ability: 800sets per month
Certificate: ISO9001:2015
HS Code: 9026100
Port: Shanghai,Qingdao,Shenzhen
Payment Type: T/T
Incoterm: FOB,CIF,EXW,CFR,FCA
CXLDS Electromagnetic Water Meter is composed of two parts: sensor and converter.
CXLDS electromagnetic water meter is an instrument made according to Faraday's law of electromagnetic induction to measure the volume flow of conducting liquid in a closed pipe.
Electromagnetic water meter is widely used in chemical industry, electric power, water supply and drainage, paper making, pharmaceutical, food, environmental protection and other departments.
1.2 Product Features
a) The measurement is not affected by changes of the fluid density, viscosity, temperature, pressure and conductivity;
b) There are no obstructing flow parts in the measuring tube and no pressure loss;
c) The sensor test signal is direct proportional to the flow rate, and the measurement range is wide;
d) Adopt low frequency square wave excitation, low power consumption, stable zero.
1.3 Working Environment
a) Ambient temperature: -25℃ ~ 55℃;
b) Ambient humidity: ≤95%RH;
c) Water temperature: 0.1℃ ~ 50℃;
d) Water pressure: 0.03Mpa ~ 1Mpa.
2 Main specifications and technical parameters
2.1 Implementation Standards
Product performance in accordance with GB 778.1-2007-T closed full pipe in the measurement of water flow application.
2.2 Key Components
The key part (component) of the electromagnetic water meter: conduit, electrode, converter, any key component plays a vital role to the overall performance of the electromagnetic water meter.
Battery power supply: 3.1V ~ 3.6V;
Dielectric conductivity: clean water > 20us/cm.
Nominal caliber: DN32, DN40, DN65, DN80, DN100, DN125, DN150, DN200, DN250, DN300.
Note: The flange is manufactured according to GB/T9119-2010.
Medium temperature: 0.1℃ ~ 50℃
Ambient temperature: (-20 ~ +60) ℃
Power: less than 1W
Accuracy level: 2
Protection level: IP68
Climatic and mechanical environmental conditions Class C
Electromagnetic environment condition level: E2
Battery life: No less than 4 years
Display: total display up to 9 digits in decimal notation, displaying forward accumulative flow, reverse accumulative flow, and net accumulative flow respectively.
Alarm information: empty pipe alarm, excitation current abnormal alarm.